Term | Main definition |
---|---|
Energy density |
For radiation. Expressed in joules per square meter.
Sometimes called irradiance.
Hits - 1513
|
Entrance facility (EF) |
A room in a building where antenna, public, and private
network service cables can enter the building and be
consolidated. Should be located as close as possible to
the entrance point. Entrance facilities are often used to
house electrical protection equipment and connecting
hardware for the transition between outdoor and indoor
cable. Also called an entrance room.
Hits - 3166
|
Entrance point |
The location where telecommunications enter a building
through an exterior wall, a concrete floor slab, a rigid
metal conduit, or an intermediate metal conduit.
Hits - 1566
|
Epoxy |
A glue that cures when mixed with a catalyzing agent.
Hits - 2117
|
Epoxy-less connector |
Hits - 1502
|
Equal level far-end crosstalk (ELFEXT) |
ELFEXT is the name for the crosstalk signal that is measured
at the receiving end and equalized by the attenuation
of the cable.
Hits - 1954
|
Equipment cable |
Cable or cable assembly used to connect telecommunications
equipment to horizontal or backbone cabling
systems in the telecommunications room and equipment
room. Equipment cables are considered to be outside the
scope of cabling standards.
Hits - 1915
|
Equipment cabling subsystem |
Part of the cabling structure, typically between the distribution
frame and the equipment.
Hits - 1509
|
Equipment room (ER) |
A centralized space for telecommunications equipment
that serves the occupants of the building or multiple
buildings in a campus environment. Usually considered
distinct from a telecommunications closet because it is
considered to serve a building or campus; the telecommunications
closet serves only a single floor. The equipment
room is also considered distinct because of the nature of
complexity of the equipment that is contained in it.
Hits - 2573
|
Erbium doped fiber amplifier (EDFA) |
An optical amplifier that uses a length of optical fiber
doped with erbium and energized with a pump laser to
inject energy into a signal.
Hits - 1462
|
Error detection |
The process of detecting errors during data transmission
or reception. Some of the error checking methods including
CRC, parity, and bipolar variations.
Hits - 1517
|
Error rate |
The frequency of errors detected in a data service line,
usually expressed as a decimal.
Hits - 2394
|
Ethernet |
A local area network (LAN) architecture developed by
Xerox that is defined in the IEEE 802.3 standard. Ethernet
nodes access the network using the Carrier Sense
Multiple Access/Collision Detect (CSMA/CD) access
method.
Hits - 3174
|
European Computer Manufacturers Association (ECMA) |
A European trade organization that issues its own specifications
and is a member of the ISO.
Hits - 1527
|
Excess loss |
(1) In a fiber-optic coupler, the optical loss from that portion
of light that does not emerge from the nominally
operational pods of the device. (2) The ratio of the total
output power of a passive component with respect to the
input power.
Hits - 1576
|